Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-7 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	24
Date	08/07/14
Start Time	15:43:59
Diameter Midpoint
 11.3	81628.2
 11.8	145798
 12.2	154120
 12.6	173874
 13.1	197141
 13.6	218560
 14.1	246464
 14.6	271546
 15.1	297880
 15.7	331224
 16.3	358089
 16.8	390970
 17.5	436679
 18.1	475987
 18.8	524308
 19.5	570803
 20.2	621147
 20.9	650148
 21.7	697779
 22.5	742307
 23.3	789856
 24.1	823690
 25.0	855579
 25.9	888646
 26.9	913780
 27.9	922316
 28.9	933501
 30.0	929586
 31.1	911382
 32.2	891427
 33.4	852328
 34.6	802657
 35.9	746839
 37.2	687064
 38.5	615777
 40.0	549104
 41.4	477717
 42.9	417442
 44.5	353689
 46.1	301294
 47.8	246804
 49.6	200254
 51.4	164092
 53.3	130131
 55.2	102255
 57.3	79561.2
 59.4	61925.5
 61.5	47606.9
 63.8	35819.7
 66.1	27118.7
 68.5	20460.4
 71.0	15463.4
 73.7	11619.4
 76.4	8343.53
 79.1	6135.81
 82.0	4526.71
 85.1	3393.39
 88.2	2437.4
 91.4	1869.89
 94.7	1341.57
 98.2	1097.83
101.8	839.311
105.5	731.752
109.4	460.993
113.4	459.833
117.6	374.404
121.9	330.889
126.3	274.565
131.0	192.11
135.8	149.298
140.7	162.701
145.9	121.408
151.2	89.2663
156.8	130.015
162.5	135.046
168.5	94.4735
174.7	82.0985
181.1	90.7928
187.7	63.0723
194.6	70.8815
201.7	63.0682
209.1	68.317
216.7	63.0434
224.7	75.2127
232.9	59.7707
241.4	50.0437
250.3	28.6398
259.5	40.3936
269.0	35.2866
278.8	40.6107
289.0	45.3206
299.6	41.0465
310.6	32.7246
322.0	27.8629
333.8	25.595
346.0	33.0049
358.7	46.2528
371.8	20.8741
385.4	37.27
399.5	18.4316
414.2	34.9273
429.4	12.3142
445.1	16.6547
461.4	8.49485
478.3	12.9724
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.7071
High Voltage	9923.66
Lower Size(nm)	11.1397
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1084.4
Median(nm)	27.2362
Mean(nm)	28.5123
Geo. Mean(nm)	26.7517
Mode(nm)	28.9026
Geo. Std. Dev.	1.43156
Total Concentration(#/cm)	2.34282e+007
Comment	